Product Manuals

Product Manuals

Choose your product to see simple steps, a how-to video and care tips.

T10 Wearable Breast Pump

  1. Charge

    Snap on the magnetic charger. A full charge lasts about 180 min (8 sessions).

  2. Assemble

    Fit the valve and flange onto the cup, then click the motor on.

  3. Wear

    Centre your nipple in the flange and slip the pump into your bra.

  4. HOLD

    Start

    Power on, pick a mode, set 1–9 with + / −. Hold Mode for heat.

  5. Pour & clean

    Pour milk into a bottle, then wash the parts.

Modes & heat
  • Massage: light, quick rhythm to start let-down.
  • Suck Simulated: feels like baby’s sucking.
  • Multitronic: mixed rhythm when flow slows.
  • Express: deeper, steady suction once milk flows.
  • Heat: press and hold the Mode button. Gentle warmth (30–38 °C) helps let-down.

Pumping should never hurt. If it does, lower the level or try another flange size.

Find your flange size
  • 19 mm
  • 21 mm
  • 24 mm
  • 28 mm

Measure the base of your nipple (not the areola) after a feed, then choose a size 2–4 mm bigger. Your nipple should move freely without rubbing.

Cleaning
  • Wash the flange, valve, seal and cup by hand after every use.
  • Sterilise these parts once a day (boil 5 min or use a steam steriliser).
  • Wipe the motor with a damp cloth. Never put it in water.
Troubleshooting
  • Weak suction: check the valve is fitted and the motor is clicked on fully.
  • Leaking: empty before the max line and stay fairly upright.
  • Won’t turn on: charge for 30 min and try again.
  • No warmth: press and hold Mode again. Warmth builds over a few minutes.

T20 Wearable Breast Pump

  1. Charge

    Connect the charging cable until fully charged.

  2. Assemble

    Fit the flange, valve and cup securely, then attach the motor.

  3. Wear

    Centre your nipple in the flange and place the pump in your bra.

  4. + / −

    Start

    Power on, choose a mode, set 1–9 with + / −. It remembers your last setting.

  5. Pour & clean

    Pour milk into a bottle, then wash the parts.

Modes
  • Massage: gently starts let-down.
  • Suck Simulated: baby-like suction.
  • Multitronic: mixed rhythm like natural nursing.
  • Express: steady expression once milk flows.

Quiet at 30–50 dB, so it’s fine at night or at work.

Cleaning
  • Wash the flange, valve, connector and cup by hand after every use.
  • Sterilise these parts once a day.
  • Wipe the motor with a damp cloth. Never put it in water.
Troubleshooting
  • Weak suction: reseat the valve and connector; check the flange seals on your skin.
  • Leaking: empty before the max line; wear a snug nursing bra.
  • Discomfort: lower the level or start in Massage mode.
  • Won’t turn on: charge for 30 min and try again.

T30 In-Bra Milk Saver

  1. Sterilise

    Before first use, boil the silicone part for 3–5 min.

  2. Squeeze gently

    A light squeeze before placing it gives a soft hold.

  3. Place in bra

    Use it on the side your baby isn’t feeding from.

  4. Pour

    Lift it off upright and pour through the spout.

Cleaning
  • Wash after every use in warm soapy water, or on the dishwasher top rack.
  • Sterilise by boiling.
  • Replace if the silicone tears or feels sticky.
Troubleshooting
  • Spills: empty more often and keep it upright.
  • Slips: wear a supportive nursing bra.
  • Uncomfortable: squeeze less before placing.

Manual EasyFlow Breast Pump

  1. Assemble

    Valve and bottle on, insert in, diaphragm pressed down, handle and cap on.

  2. Position

    Lean forward a little and seal the cushion around your nipple.

  3. Squeeze & release

    Quick, short presses to start, then slow, steady presses as milk flows.

  4. 150 ml

    Collect

    Unscrew the bottle, then cap it or pour into a storage bag.

Parts
  • Handle, silicone diaphragm, top cap
  • Flange connector and soft silicone insert (24 mm or 28 mm)
  • Duckbill valve and 150 ml bottle
Cleaning
  • Take apart and wash every part after use.
  • Sterilise once a day.
  • Replace the valve or diaphragm if torn or stretched.
Troubleshooting
  • No suction: press the diaphragm down all round; check the valve is on.
  • Milk in the handle area: the diaphragm isn’t seated. Dry it and refit.
  • Discomfort: use lighter presses or try the other insert size.

4-in-1 Baby Food Maker

  1. 1–2 cm

    Cut small

    Wash, peel and cut food into small, even cubes.

  2. Fill the tank

    Pour clean water into the tank on top.

  3. Add food

    Blade in, food in, lid on. Lock the jar onto the base.

  4. Press Steam

    Steam doesn’t stop by itself. Time it (see guide below).

  5. HOLD

    Hold Blend

    Press and hold Blend. Release to stop. Pulse for a lumpier texture.

Steaming guide: fruit 8 min · leafy veg 12 min · root veg 18 min · meat & poultry 22 min. Stay nearby while steaming and switch it off when time is up.
Textures for each stage
  • First tastes: blend longer for a silky purée.
  • Next stage: a few short pulses for soft lumps.
  • Self-feeding: steam only, or one or two pulses.
Cleaning
  • Unplug and let it cool first.
  • Hand wash the jar, lid and blade after use. Hold the blade by its grey hub.
  • Wipe the base with a damp cloth. Never put it in water.
  • Descale the tank monthly: half white vinegar, half water, leave 30 min, then rinse.
Troubleshooting
  • Won’t start: check the jar and lid are fully locked.
  • Undercooked: cut smaller pieces or steam a little longer.
  • Blade stuck: too much food. Remove some or add a little liquid.
  • White marks in tank: limescale. Descale as above.

Quick-Warm Bottle Warmer

  1. Bottle in

    Place the bottle in the anti-scald basket.

  2. Add water

    Fill the chamber to about the milk level.

  3. + / −

    Choose & set

    Power on, pick a mode, set the temperature (37 °C = body temp).

  4. Test & feed

    Lift out by the basket, swirl, and test a few drops on your wrist.

Modes & buttons
  • Fast: quickest, about 3 min to 37 °C.
  • Warm: gentle, steady warming.
  • Keep: holds milk at temperature.
  • Defrost: thaws frozen milk bags or bottles.
  • Food: warms baby food jars and pouches.
  • Sterilize: steam-cleans teats and small parts.
  • Moon button: soft night light. Timer: set a run time with + / −.
Milk safety
  • Never microwave breast milk.
  • Use warmed milk within 1–2 hours. Don’t re-warm leftovers.
Cleaning
  • Unplug, let it cool, and empty the water after each use.
  • Lift out the heating disc to clean underneath.
  • Hand wash the basket and lid. Never put the base in water.
  • Descale every 2–4 weeks: half white vinegar, half water, 30 min, rinse.
Troubleshooting
  • Switches off: the water ran low (dry-burn protection). Let it cool, add water, restart.
  • Too warm / too cool: adjust the set temperature and match water to milk level.
  • Slow to warm: descale the plate; cold or large bottles take longer.
General safety
  • Check parts before each use. Replace anything cracked or torn.
  • Keep small parts and cables away from children.
  • Use only the supplied chargers. Keep motors and bases away from water.
  • Pain, cracked nipples, fever or a hot red area? Stop and see your doctor or a lactation consultant.

Need help?

We’re happy to help with setup, sizing or warranty.

Contact us